Search...
Menu

Sangfor Subscription Cloud POC Guide

1 Introduction

The POC tests are to verify whether Sangfor Subscription Cloud Platform can meet the relevant construction requirements of customers.

1.1 Objectives

To verify the following:

1.     Sangfor Cloud Platform (SCP) login security and isolation for tenants and administrators.

2.     SCP operations capabilities, including management of multi-level accounts, account authentication, and images.

3.     SCP advanced features, including aSecurity, Application Center, disaster recovery, etc.

1.2 Key Information

Date and Time

 

Location

 

Personnel

 

Phone Number

 

1.3 Requirements

1.     Before testing, carefully check the feature items to be tested and correspondingly delete the contents that do not need to be tested, and ensure that the testing environments have been prepared.

2.     During testing, confirm the testing process and results with the customer one by one, and save the corresponding screenshots.

3.     After testing, deliver the overall test report to the relevant personnel.

 

Preparations

2.1 Customer

Item

Description

Server Room

Racks, trays, PDU power supplies, and appropriate network environments to ensure that tests can be performed properly.

Servers

Compliant servers if needed.

2.2 Sangfor

Item

Description

Hardware and Software

Servers, HCI and SCP software, needed templates, and so on. For details, refer to Section 2.3 Hardware and Software List.

Confirmation of Customer’s Environments

Ensure that the customer has prepared the appropriate testing environments and requirements according to the Environment Checklist.

2.3 Hardware and Software List (Supplemental Devices)

No.

Type

Model

Use

Number

Remarks

1

Server

W-2205

Hyper-Converged Infrastructure (HCI) Cluster Creation

2

A supplemental device in a storage-computing splitting architecture.

2

USB Flash Drive

8 GB

Disk Installation and Burning

1

 

 

Environments

3.1 Topology

Four Gigabit Ethernet Layer 2 switches are required to connect six hosts in the following topology. Please connect the management switch to the switch connected to the edge-connected interface so that the management and business network segments can communicate with each other (or multiplex a Gigabit Ethernet switch that supports VLAN segregation and allows access to the management VLAN in the business VLAN).

3.2 IP Address Planning (Modified as Needed)

Please configure the host IP addresses and networks for the tests as follows:

Resource

IP Type

IPs/IP Range

Netmask

Remarks

HCI Cluster 1 (Existing)

Management Interface IP

172.16.200.101-103 255.255.255.0

255.255.255.0

eth0.

VXLAN IP

10.10.10.1-g10 255.255.255.0

255.255.255.0

eth1-eth2.

Storage Area Network IP

100.100.100.1-10 255.255.255.0

255.255.255.0

eth3-eth4.

Elastic IP Pool

172.16.200.201-220 255.255.255.0

255.255.255.0

eth5.

HCI Cluster 2 (Added)

Management Interface IP

172.16.200.111-113 255.255.255.0

255.255.255.0

eth0.

VXLAN IP

20.20.20.1-10 255.255.255.0

255.255.255.0

eth1-eth2.

Storage Area Network IP

200.200.200.1-10 255.255.255.0

255.255.255.0

eth3-eth4.

Elastic IP Pool

172.16.200.221-240 255.255.255.0

255.255.255.0

eth5.

SCC (Deployed on HCI Cluster 2)

Management interface IP

172.16.200.200 255.255.255.0

255.255.255.0

 

Shared Service Elastic IP Pool

200.200.20.10-200.200.20.100 255.255.255.0

255.255.255.0

For all resource pools. eth5.

Shared Service Elastic IP Pool Gateway

200.200.20.1 255.255.255.0

255.255.255.0

 

Shared Service IP

200.200.20.1 255.255.255.0

255.255.255.0

 

Cloud Security Service Platform Management IP

172.16.200.210 255.255.255.0

255.255.255.0

 

Cloud Security Service Platform Service IP

200.200.20.210 255.255.255.0

255.255.255.0

 

Ethernet Switch

Management Interface IP

172.16.200.105-109 255.255.255.0

255.255.255.0

 

 

Network Plane

Aggregation Mode

Switch Interface Type

Load Balancing Mode

VLAN

Management Network

N/A

access

Manual Load Sharing Mode

200

VXLAN Network

Load Based on IP Addresses

access

Manual Load Sharing Mode

201

Business Network

N/A

trunk

Manual Load Sharing Mode

N/A

Storage Area Network

Link Aggregation with Two Switches

access

Manual Load Sharing Mode

202/203

 

Share this Article
Previous
Sangfor_SKE1_1_0_Upgrade_Guide__1_
Next
User Manual